Search results for "Small diameter"

showing 9 items of 9 documents

Discussion of “Analysis of Geometrical Relationships and Friction Losses in Small-Diameter Lay-Flat Polyethylene Pipes” by Giuseppe Provenzano, Vince…

2016

For a lay-flat drip line with an inner nominal diameter dn = 16 mm, characterized by three different pipe wall thicknesses, WT, 6, 8 and 10 mil, the Authors of the original paper very accurately investigated the geometrical expansion of the cross-sectional diameter as a function of different pressure head values, ranging in between 0.84-17.55 m. Results obtained by the Authors, for pressure heads not exceeding a threshold pressure value, showed significant d variations, in a very narrow range of pressure heads, which however is seldom considered in practice (less than 3 m). The Authors experimentally evaluated a modified Blasius’ law friction coefficient, c, equal to 0.285, corresponding to…

EngineeringSmall diameterPolymer sciencebusiness.industry0208 environmental biotechnologyLay-flat polyethylene pipes Pipe geometry Hydraulic radius Friction losses non-uniform flow04 agricultural and veterinary sciences02 engineering and technologyPolyethyleneAgricultural and Biological Sciences (miscellaneous)020801 environmental engineeringchemistry.chemical_compoundchemistry040103 agronomy & agriculture0401 agriculture forestry and fisheriesSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestalibusinessWater Science and TechnologyCivil and Structural Engineering
researchProduct

Analysis of Geometrical Relationships and Friction Losses in Small-Diameter Lay-Flat Polyethylene Pipes

2016

[EN] The use of lay-flat polyethylene pipes to irrigate horticultural crops has been receiving widespread attention in the last decade, due to the significant improvements in their hydraulic performance, their potentially high application efficiency, and their limited installation costs. However, even if hydraulic design procedures for conventional microirrigation systems are fairly well established, there is still the need to know how different pipe-wall thicknesses of lay-flat pipes can affect the pipe geometry under different operating pressures as well as the related consequences on friction losses. This paper, after comparing two different procedures (caliper and photographic) to asses…

Friction factorSmall diameterHydraulic engineeringeducation0208 environmental biotechnologyHorticultural cropsLay-flat polyethylene pipe02 engineering and technologychemistry.chemical_compoundFriction lossesGeotechnical engineeringWater Science and TechnologyCivil and Structural EngineeringLay-flat polyethylene pipes; Pipe geometry; Hydraulic radius; Friction losses; Friction factorFriction losseHydraulic radiufood and beverages04 agricultural and veterinary sciencesPolyethyleneAgricultural and Biological Sciences (miscellaneous)020801 environmental engineeringPipe geometryFriction factorHydraulic radiuschemistry040103 agronomy & agricultureINGENIERIA AGROFORESTAL0401 agriculture forestry and fisheriesLay-flat polyethylene pipesGeologyJournal of Irrigation and Drainage Engineering
researchProduct

A PARAMETERS’ SYNTHESIS OF GRINDING PROCESS MODELING FOR CARBIDE DRILLS DEEP HOLES AND SMALL DIAMETER

2013

Grinding processMaterials scienceSmall diameterlcsh:Tlcsh:Mechanical engineering and machineryMetallurgyMechanical engineeringlcsh:TJ1-1570General Medicinelcsh:TechnologyCarbideAnnals of the Oradea University: Fascicle Management and Technological Engineering
researchProduct

LDA+Uand tight-binding electronic structure of InN nanowires

2013

In this paper we employ a combined ab initio and tight-binding approach to obtain the electronic and optical properties of hydrogenated Indium nitride InN nanowires. We first discuss InN band structure for the wurtzite structure calculated at the LDA+U level and use this information to extract the parameters needed for an empirical tight-binging implementation. These parameters are then employed to calculate the electronic and optical properties of InN nanowires in a diameter range that would not be affordable by ab initio techniques. The reliability of the large nanowires results is assessed by explicitly comparing the electronic structure of a small diameter wire studied both at LDA+U and…

Indium nitrideSmall diameterMaterials scienceCondensed Matter - Mesoscale and Nanoscale PhysicsCondensed matter physics: Physics [G04] [Physical chemical mathematical & earth Sciences]Ab initioNanowireFOS: Physical sciencesPhysics::OpticsElectronic structureCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsCondensed Matter::Materials Sciencechemistry.chemical_compoundTight binding: Physique [G04] [Physique chimie mathématiques & sciences de la terre]chemistryMesoscale and Nanoscale Physics (cond-mat.mes-hall)Electronic band structureWurtzite crystal structurePhysical Review B
researchProduct

Microlaparoscopic Hernia Repair in Children

2011

Introduction. This study reports the authors’ experience with the exclusive use of 2-mm instrument sets and small diameter scopes in 100 children undergoing microlaparoscopic herniorrhaphy. Method. This prospective study was designed as a pilot feasibility study; all data related to patients and procedures were prospectively collected. A pneumoperitoneum was established, and 1.7 to 2 mm 0° or 30° scopes were introduced for visualization. Exclusively 2-mm instruments were used. Results. This study included 100 children (aged 15 days to 11 years, median age 2.3 years) undergoing microlaparoscopic hernia repair. A total of 140 hernias were treated. The average operative time for the microlapa…

MaleMicrosurgerymedicine.medical_specialtySmall diametermedicine.medical_treatmentHernia InguinalPilot ProjectsPneumoperitoneummedicineHumansProspective StudiesChildProspective cohort studyHerniorrhaphybusiness.industryInfant NewbornInfantmedicine.diseaseHernia repairSurgeryInguinal herniaTreatment OutcomeHernia recurrenceChild PreschoolFeasibility StudiesOperative timeFemaleLaparoscopySurgerybusinessSurgical Innovation
researchProduct

Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…

2015

OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…

RoxolidMaleSmall diameterSLActive surfaceDentistrychemistry.chemical_elementMandibleCONVENTIONAL COMPLETE DENTURESlaw.inventionDouble blindRETROSPECTIVE EVALUATION IMPLANTDouble-Blind MethodRandomized controlled triallawMARGINAL BONE LOSSHumansJaw EdentulousMedicineMANDIBULAR 2-IMPLANT OVERDENTURES610 Medicine & healthAgedDental ImplantsTitaniumPATIENT SATISFACTIONTitanium/zirconiumSTRESS-DISTRIBUTIONbusiness.industryDental Implantation Endosseoustechnology industry and agricultureWITHIN-SUBJECT COMPARISONSSoft tissueDIFFERENT LOADING PROTOCOLSDenture Overlayequipment and suppliesTitanium zirconiumddc:617.6Treatment OutcomeDental Prosthesis DesignchemistryImplant typesedentulousFemaleZirconiumImplantFINITE-ELEMENT-ANALYSISOral SurgerybusinessDental AlloysTitaniumClinical Oral Implants Research
researchProduct

Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…

2015

BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …

RoxolidSmall diameterSplit-mouthDentistrychemistry.chemical_element610 Medicine & healthMandiblelaw.inventionTiZrDouble blindstomatognathic systemRandomized controlled trialDouble-Blind MethodlawOverdenturesAlloysMedicineHumansJaw Edentulous610 Medicine & healthGeneral DentistrySurvival rateOrthodonticsDental ImplantsTitaniumbusiness.industryDentistry(all)Ti Grade IVDental Implantation Endosseoustechnology industry and agricultureSLActiveequipment and suppliesDenture OverlayTitanium zirconiumddc:617.6stomatognathic diseaseschemistryDental Prosthesis DesignOral and maxillofacial surgeryImplantZirconiumbusinessTitaniumFollow-Up StudiesResearch Article
researchProduct

Wet-chemical approach for the cell-adhesive modification of polytetrafluoroethylene

2011

Polytetrafluoroethylene (PTFE), a frequently utilized polymer for the fabrication of synthetic vascular grafts, was surface-modified by means of a wet-chemical process. The inherently non-cell-adhesive polymer does not support cellular attachment, a prerequisite for the endothelialization of luminal surface grafts in small diameter applications. To impart the material with cell-adhesive properties a treatment with sodium-naphthalene provided a basis for the subsequent immobilization of the adhesion promoting RGD-peptide using a hydroxy- and amine-reactive crosslinker. Successful conjugation was shown with cell culture experiments which demonstrated excellent endothelial cell growth on the m…

Umbilical VeinsMaterials scienceSmall diameterPolymersSurface PropertiesCellCell Culture TechniquesBiomedical EngineeringBioengineeringNaphthalenesBiomaterialschemistry.chemical_compoundCell AdhesionmedicineHumansComposite materialPolytetrafluoroethylenechemistry.chemical_classificationPolytetrafluoroethyleneSodiumEndothelial CellsPolymerAdhesionCross-Linking Reagentsmedicine.anatomical_structureChemical engineeringchemistryCell cultureAdsorptionAdhesiveOligopeptidesEndothelial cell growthBiomedical Materials
researchProduct

Diameter 2 properties and convexity

2015

We present an equivalent midpoint locally uniformly rotund (MLUR) renorming $X$ of $C[0,1]$ on which every weakly compact projection $P$ satisfies the equation $\|I-P\| = 1+\|P\|$ ($I$ is the identity operator on $X$). As a consequence we obtain an MLUR space $X$ with the properties D2P, that every non-empty relatively weakly open subset of its unit ball $B_X$ has diameter 2, and the LD2P+, that for every slice of $B_X$ and every norm 1 element $x$ inside the slice there is another element $y$ inside the slice of distance as close to 2 from $x$ as desired. An example of an MLUR space with the D2P, the LD2P+, and with convex combinations of slices of arbitrary small diameter is also given.

Unit sphereSmall diameter46B04 46B20General Mathematics010102 general mathematicsRegular polygon01 natural sciencesMidpointConvexityFunctional Analysis (math.FA)Mathematics - Functional Analysis010101 applied mathematicsCombinatoricsNorm (mathematics)FOS: Mathematics0101 mathematicsMathematicsStudia Mathematica
researchProduct